To the top

Page Manager: Webmaster
Last update: 9/11/2012 3:13 PM

Tell a friend about this page
Print version

Reexamination of Accelero… - University of Gothenburg, Sweden Till startsida
Sitemap
To content Read more about how we use cookies on gu.se

Reexamination of Accelerometer Calibration with Energy Expenditure as Criterion: VO2net Instead of MET for Age-Equivalent Physical Activity Intensity

Journal article
Authors Daniel Arvidsson
Jonatan Fridolfsson
C. Buck
O. Ekblom
E. Ekblom-Bak
Lauren Lissner
Monica Hunsberger
Mats Börjesson
Published in Sensors
Volume 19
Issue 15
ISSN 1424-8220
Publication year 2019
Published at Institute of Medicine, School of Public Health and Community Medicine
Institute of Neuroscience and Physiology
Department of Food and Nutrition, and Sport Science
Language en
Links dx.doi.org/10.3390/s19153377
Keywords physical activity, accelerometer, VO2, calibration, MET, VO2net, speed, equivalent speed, free-living, computer-science, cost, walking, validation, efficiency, validity, monitor, Chemistry, Electrochemistry, Instruments & Instrumentation
Subject categories Electrochemistry

Abstract

Accelerometer calibration for physical activity (PA) intensity is commonly performed using Metabolic Equivalent of Task (MET) as criterion. However, MET is not an age-equivalent measure of PA intensity, which limits the use of MET-calibrated accelerometers for age-related PA investigations. We investigated calibration using VO2net (VO2gross - VO2stand; mL.min(-1).kg(-1)) as criterion compared to MET (VO2gross/VO2rest) and the effect on assessment of free-living PA in children, adolescents and adults. Oxygen consumption and hip/thigh accelerometer data were collected during rest, stand and treadmill walk and run. Equivalent speed (Speed(eq)) was used as indicator of the absolute speed (Speed(abs)) performed with the same effort in individuals of different body size/age. The results showed that VO2net was higher in younger age-groups for Speedabs, but was similar in the three age-groups for Speed(eq). MET was lower in younger age-groups for both Speed(abs) and Speed(eq). The same VO2net-values respective MET-values were applied to all age-groups to develop accelerometer PA intensity cut-points. Free-living moderate-and-vigorous PA was 216, 115, 74 and 71 min/d in children, adolescents, younger and older adults with VO2net-calibration, but 140, 83, 74 and 41 min/d with MET-calibration, respectively. In conclusion, VO2net calibration of accelerometers may provide age-equivalent measures of PA intensity/effort for more accurate age-related investigations of PA in epidemiological research.

Page Manager: Webmaster|Last update: 9/11/2012
Share:

The University of Gothenburg uses cookies to provide you with the best possible user experience. By continuing on this website, you approve of our use of cookies.  What are cookies?